Commercial Water Heater / Boiler Install & Replacement in Orange County, CA
Restaurants, gyms, multifamily, schools, and light industrial facilities need reliable, right-sized hot water with safe temperatures and minimal downtime. White Glove Plumbing & Restoration designs and installs commercial water heaters and boiler-based DHW plants—from high-input tanks to condensing boiler + indirect tanks and tankless racks—with proper venting, gas/electrical capacity, recirc balance, mixing, and controls.
✓ Proof of work: start-up data and reports
✓ Right-sizing: capacity matched to peak load
✓ High efficiency: condensing options and controls
✓ Minimal downtime: temp heat and phased swaps
✓ Proof of work
✓ Right-sizing
✓ High efficiency
✓ Minimal downtime



What Is Commercial Water Heater / Boiler Install & Replacement?
A turnkey project to remove and replace your commercial DHW equipment with right-sized, code-compliant systems: high-input storage heaters, boiler + indirect tanks, volume water heaters, or tankless rack systems.
We handle design, rigging, utilities, vent/condensate, recirculation, mixing/anti-scald, start-up, and documentation.
Why Choose White Glove Plumbing
Compliance & safety first: Permit/inspection, ASME/UPC details, combustion air, Category II/III/IV venting, condensate neutralization, seismic anchoring.
Defensible documentation: Commissioning logs (inlet gas pressure, CO/draft, temp rise, pump curves), photos, and O&M packet.
Beyond a swap: Recirc balancing, master mixing valves, BMS tie-in, water treatment/softening, expansion/backflow, and insulation.
One accountable team: Temporary hot water, rigging/crane, electrical/gas upgrades, and N+1 redundancy planning—end to end.



Immediate Actions (What to Do Now)
Share recent issues (no hot water, temperature swings, trips, leaks).
Gather specs (BTU/input, storage gallons, voltage, vent type) and photos of the plant.
Note your peak times (showers, laundry, kitchen rush) and recirc layout.
Identify constraints (access, crane needs, shutdown windows, after-hours only).
Call our 24/7 dispatcher—we’ll assess load, logistics, and code items, then schedule a safe, phased replacement.
Common Situations We Handle
Aging plants with frequent lockouts or leaks
Capacity shortfalls during morning shower or kitchen peaks
Inefficient non-condensing units and failing flues
Improper temps (scald risk or lukewarm complaints)
Unbalanced recirc loops causing hot-then-cold at distant fixtures
Change of use/tenant requiring larger or smaller systems
Assessment & Design
Load calc from fixture counts/usage; choose tank, boiler+indirect, or rack; confirm gas/electric capacity; specify mixing, recirc, and controls.
Permits & Logistics
Pull permits; plan rigging/crane, access, traffic/after-hours; stage temporary hot water if required.
Demo & Prep
Safe lockout/tagout; drain and remove equipment; correct gas regulators, electrical feeds, slab/stand, and penetrations.
Set, Pipe & Vent
Install equipment; run Category-rated vent/intake, condensate with neutralizer, full-port valves, expansion/backflow, and primary/secondary piping as designed.
Commissioning & Balance
Purge/flush; verify inlet gas pressure, CO/draft, temp rise, pump speed/ΔP; set master mixing (~120°F distribution policy-compliant) and balance recirc.
Handover & Documentation
Train staff; deliver as-built photos, start-up logs, warranty/serials, maintenance schedule, and inspection notes.
What’s Included
Load calculation & equipment specification
Permitting, rigging, and safe demo
Code-correct venting/intake & condensate neutralizer
Gas/electrical/water piping with valves, expansion & backflow
Start-up, mixing setpoint, and recirc balancing
Commissioning packet (photos, readings, O&M/warranty)

Costs & Timelines (What to Expect)
Aging plants with frequent lockouts or leaks
Capacity shortfalls during morning shower or kitchen peaks
Inefficient non-condensing units and failing flues
Improper temps (scald risk or lukewarm complaints)
Unbalanced recirc loops causing hot-then-cold at distant fixtures
Change of use/tenant requiring larger or smaller systems

Insurance & Compliance Support
Records your stakeholders expect: COIs, permits, pressure/gas/CO logs, mixing setpoint, and recirc readings.
Policy alignment: Local plumbing/mechanical codes, ASME where applicable, backflow/cross-connection requirements.
Inspection-ready: Labeling, clearances, combustion air, seismic, and documentation delivered.

Risks of Waiting (Why Act Now)
Unplanned outages and revenue loss
Scald or water-safety risks from unstable temps or undersized mixing
High utility bills from aging, non-condensing equipment
Leak/failure damage and emergency premiums for after-hours fixes

Methods, Materials & Quality Standards
Category-rated venting (stainless/PP/PVC per listing) with proper slope and supports; condensate neutralized to approved drain.
Full-port valves, purge points, gauges, and union isolation for service.
ASME/NSF components where required; low-lead potable fittings.
Controls: Lead/lag or N+1 logic, aquastats/sensors placed for true readings, optional BMS integration.
Thermal strategy: Storage or plant above policy temp with master mixing ~120°F distribution and documented recirc balance.
Insulation & labeling: Piping and devices labeled for fast maintenance.
Frequently Asked Questions
Tank, boiler + indirect, or tankless rack—what’s best?
We size to your peak draw, footprint, and utility capacity. Racks excel at modulation and serviceability; boiler+indirect offers large storage with high recovery; high-input tanks are simple and compact.
Will we lose hot water during the changeout?
We can phase work or provide temporary hot water to maintain operations.
What temperature do you set?
We follow your water safety policy—often higher storage with a master mixing valve for ~120°F distribution to outlets.
Do we need water treatment?
Often yes: softening/scale control protects exchangers and maintains efficiency; we’ll recommend based on water quality.
Can you tie into our BMS?
Yes—lead/lag, alarms, and temps can report to your building management system.
Do you provide N+1 redundancy?
We can configure plants to run at demand with one unit in reserve for reliability.

More White Glove Plumbing Hot Water System Services
Proudly Serving All of Orange County
Address: 1430 E Borchard Ave, Santa Ana, CA 92705
Phone: (949) 209-5206
Email: office@whitegloveplumbingca.com
White Glove Plumbing is locally based in Santa Ana and serves residential and commercial clients across Orange County with 24/7 emergency plumbing and water-damage restoration.
Our expert team handles leak detection, emergency plumbing, water extraction/dry-out, sewage cleanup, mold remediation, and reconstruction in top OC areas including Irvine, Anaheim, Santa Ana, Orange, Tustin, Costa Mesa, Newport Beach, Huntington Beach, Mission Viejo, Lake Forest, Fullerton, Yorba Linda, Laguna Beach, Dana Point, and San Clemente - plus surrounding neighborhoods.
Let’s start a conversation
Book Your Free Consultation call Now
Contact us:
CALL (949) 209-5206
1430 E Borchard Ave, Santa Ana, CA 92705